Maximum efficiency of a transformer depends on:
(A) The working condition
(B) Whether copper loss = 1/2x iron loss
(C) Whether copper loss = iron loss
(D) Whether copper loss = 2x iron loss
Answer
638.1k+ views
Hint: In general efficiency is defined as the ratio of output vs input and greater be the efficiency the more productive is the machine is. The efficiency of the transformer is defined as the ratio of useful output parts to the input power. The input and the output are measured in the same unit.
Complete step by step solution:
\[r=\dfrac{output\,\,power}{input\,\,power}=\dfrac{output\,\,power}{output\,\,power\,\,+\,\,loss}\]
\[r=\dfrac{output\,\,power}{input\,\,power\,\,+\,\,iron\,\,loss\,\,+\,\,copper\,\,loss}\]
\[r=\dfrac{{{V}_{2}}{{I}_{2}}\cos {{\phi }_{2}}}{{{v}_{2}}{{I}_{2}}\,\,ocs{{\phi }_{2}}+{{P}_{i}}+{{P}_{c}}}\] …(1)
Where
\[{{V}_{2}}\to \] Secondary terminal voltage.
\[{{I}_{2}}\to \] Full load secondary current
\[\operatorname{Cos}{{\phi }_{2}}\to \] Iron losses = hysteresis loss + eddy current loss
\[{{P}_{C}}=\] Full load copper
From equation (1)
\[M=\dfrac{{{V}_{2}}\,\,{{I}_{2}}\,\,\cos {{\phi }_{2}}}{{{v}_{2}}\,\,{{I}_{2}}\,\,\cos {{\phi }_{2}}+Pi+I_{2}^{2}\,\,\operatorname{Re}s}\]
\[M=\dfrac{{{V}_{2}}\,\cos {{\phi }_{2}}}{{{v}_{2}}\,\,\cos {{\phi }_{2}}+\dfrac{Pi}{{{I}_{2}}}+{{I}_{2}}\operatorname{Re}s}\] …(2)
The value of terminal voltage \[{{V}_{2}}\]is approximately constant. Thus, for a given power factor i.e. transformer efficiency depends upon the load current \[{{I}_{2}}\]. In eq. (2), the numerator is constant and the transformer efficiency will be maximum if the denominator with respect to variable \[{{I}_{2}}\] is equated to zero.
\[\dfrac{d}{d{{I}_{2}}}\left( {{V}_{2}}\cos {{\phi }_{2}}+\dfrac{Pi}{{{I}_{2}}}{{I}_{2}}\operatorname{Re}s \right)=0\]
\[0-\dfrac{pi}{I_{2}^{2}}+\operatorname{Re}s=0\] \[\] …(3)
\[{{m}_{\max }}=\dfrac{{{V}_{2}}{{I}_{2}}\cos {{\phi }_{2}}}{{{V}_{2}}{{I}_{2}}\cos {{\phi }_{2}}+2Pi} as\,\,\left( P_c=P_i \right)\]
Hence, while seeing all the above equations we got the final result that the transformati
Thus, the transformer will give the maximum efficiency when their copper loss is equal to iron loss.
Hence the correct option is (c)
Note: Efficiency of a transformer depends upon many factors: its build quality, the material used, the flux loss etc.
The efficiency of the transformer is defined as the ratio of useful output parts to the input power.
Complete step by step solution:
\[r=\dfrac{output\,\,power}{input\,\,power}=\dfrac{output\,\,power}{output\,\,power\,\,+\,\,loss}\]
\[r=\dfrac{output\,\,power}{input\,\,power\,\,+\,\,iron\,\,loss\,\,+\,\,copper\,\,loss}\]
\[r=\dfrac{{{V}_{2}}{{I}_{2}}\cos {{\phi }_{2}}}{{{v}_{2}}{{I}_{2}}\,\,ocs{{\phi }_{2}}+{{P}_{i}}+{{P}_{c}}}\] …(1)
Where
\[{{V}_{2}}\to \] Secondary terminal voltage.
\[{{I}_{2}}\to \] Full load secondary current
\[\operatorname{Cos}{{\phi }_{2}}\to \] Iron losses = hysteresis loss + eddy current loss
\[{{P}_{C}}=\] Full load copper
From equation (1)
\[M=\dfrac{{{V}_{2}}\,\,{{I}_{2}}\,\,\cos {{\phi }_{2}}}{{{v}_{2}}\,\,{{I}_{2}}\,\,\cos {{\phi }_{2}}+Pi+I_{2}^{2}\,\,\operatorname{Re}s}\]
\[M=\dfrac{{{V}_{2}}\,\cos {{\phi }_{2}}}{{{v}_{2}}\,\,\cos {{\phi }_{2}}+\dfrac{Pi}{{{I}_{2}}}+{{I}_{2}}\operatorname{Re}s}\] …(2)
The value of terminal voltage \[{{V}_{2}}\]is approximately constant. Thus, for a given power factor i.e. transformer efficiency depends upon the load current \[{{I}_{2}}\]. In eq. (2), the numerator is constant and the transformer efficiency will be maximum if the denominator with respect to variable \[{{I}_{2}}\] is equated to zero.
\[\dfrac{d}{d{{I}_{2}}}\left( {{V}_{2}}\cos {{\phi }_{2}}+\dfrac{Pi}{{{I}_{2}}}{{I}_{2}}\operatorname{Re}s \right)=0\]
\[0-\dfrac{pi}{I_{2}^{2}}+\operatorname{Re}s=0\] \[\] …(3)
\[{{m}_{\max }}=\dfrac{{{V}_{2}}{{I}_{2}}\cos {{\phi }_{2}}}{{{V}_{2}}{{I}_{2}}\cos {{\phi }_{2}}+2Pi} as\,\,\left( P_c=P_i \right)\]
Hence, while seeing all the above equations we got the final result that the transformati
Thus, the transformer will give the maximum efficiency when their copper loss is equal to iron loss.
Hence the correct option is (c)
Note: Efficiency of a transformer depends upon many factors: its build quality, the material used, the flux loss etc.
The efficiency of the transformer is defined as the ratio of useful output parts to the input power.
Recently Updated Pages
Write structures of the following compounds i 2 Chloro3methylpentane class 11 chemistry CBSE

What is BLO What is the full form of BLO class 8 social science CBSE

Explain the Treaty of Vienna of 1815 class 10 social science CBSE

A Paragraph on Pollution in about 100-150 Words

XIX+XXX A 49 B 51 C 55 D 44 class 5 maths CBSE

If x a + bt + ct2 where x is in meters and t is in class 11 physics CBSE

Trending doubts
One Metric ton is equal to kg A 10000 B 1000 C 100 class 11 physics CBSE

Find the value of the expression given below sin 30circ class 11 maths CBSE

What do you mean by retardation What is its SI uni class 11 physics CBSE

Draw a diagram of nephron and explain its structur class 11 biology CBSE

10 examples of friction in our daily life

Difference between physical and chemical change class 11 chemistry CBSE